Alpha Microsystems Eagle 100 Instalační příručka Strana 29

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 42
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 28
Page 3-12 Chapter Three
AlphaNET Installation Guide, Revision 05
This is similar to the traditional TRMDEF statement. The #10 causes 10 TCBs with associated terminal
buffers to be made available for use by remote job connections.
You can have only one TRMDEF #count statement in your initialization file. If you have more than one,
all of them after the first are ignored.
For best results, the special TRMDEF statement described above should be the last TRMDEF
statement in your system initialization command file.
In AMOS 2.3 and later, each TCB you allocate in this way counts as a user toward your AMOS license.
Therefore, the total number of real terminals defined in your initialization file plus the number of TCBs
defined by TRMDEF #count must be equal to or less than your AMOS user license. If you try to allocate
more TCBs than you have jobs available, you see an error message and only the number of TCBs you
have available under your AMOS license are allocated.
Creating Communication Zone (Type 2 CONECT Support)
In order to support remote connections requested by CONECT, the host computer must have a special
communication zone defined in the initialization command file. This zone is part of the interface
between the Ethernet network driver and the spawned jobs created as the result of a CONECT connection
request. To set up this area, an ETHZON statement must be added to the system initialization command
file. The syntax is simply:
ETHZON maxjobs
maxjobs is the maximum number of CONECT connections to be supported at any given time. The
maxjobs number should match the number listed in the special TRMDEF statement described above.
Example:
ETHZON 10
This statement, when added to your system initialization command file, would allocate an Ethernet
communication zone large enough to support a maximum of 10 virtual terminal connections created by a
CONECT request. Make sure you insert the ETHZON statement after the TRMDEF statements and
before the first NETINI command.
TESTING THE NEW INITIALIZATION COMMAND FILE
After making the changes described above, log into DSK0:[1,2] and test your new initialization
command file using the MONTST command. For AMOS/L systems, enter:
MONTST AMOSL.MON,TEST.INI
RETURN
For AMOS/32 systems, enter:
MONTST AMOS32.MON,TEST.INI
RETURN
If the computer doesn’t reboot properly, press your computer’s RESET button to reboot under your
original initialization file. Re-check TEST.INI for mistakes and try again.